Model
Indoor CS-VZ12SKE
Outdoor CU-VZ12SKE
Piping
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 9.52 (3/8)
Standard length m (ft) 5.0 (16.4)
Length range (min – max) m (ft) 3 (9.8) ~ 15 (49.2)
I/D & O/D Height different m (ft) 5.0 (16.4)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Length for Additional Gas m (ft) 7.5 (24.6)
Drain Hose
Inner Diameter mm 16.2
Length mm 650
Indoor Heat
Exchanger
Fin Material Aluminium (Pre Coat)
FPI 20.5
Outdoor Heat
Exchanger
Fin Material Aluminium (Pre Coat)
Fin Type Corrugated Fin (2LT-C6S-L)
Row × Stage × FPI 2 × 32 × 19
Size (W × H × D) mm 809.5:789.7 × 586.24 × 25.2
Power Supply Indoor Power Supply
Power Supply Cord A Nil
Thermostat Electronic Control
Protection Device Electronic Control
DRY BULB WET BULB
Indoor Operation
Range
Cooling
Maximum 32 23
Minimum 16 11
Heating
Maximum 30
Minimum 16
+8/10°C HEAT
Maximum 10
Minimum 16
Outdoor Operation
Range
Cooling
Maximum 43 26
Minimum -10
Heating
Maximum 24 18
Minimum -30
+8/10°C HEAT
Maximum
Minimum -30
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3. Specifications are subjected to change without prior notice for further improvement.