169
19.2 Heat Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Heat mode at 30°C
Voltage: 230V
19.2.1 CS-VZ9SKE CU-VZ9SKE
Indoor (°C) Outdoor DB (°C)
DB
-20 2 7
TC IP TC IP TC IP
24 4.63 2.41 5.56 2.48 7.86 2.72
20 4.70 2.36 5.70 2.41 7.90 2.72
16 4.84 2.24 5.93 2.28 8.06 2.72
19.2.2 CS-VZ12SKE CU-VZ12SKE
Indoor (°C) Outdoor DB (°C)
DB
-20 2 7
TC IP TC IP TC IP
24 4.93 2.69 6.53 2.88 9.15 3.16
20 5.00 2.63 6.70 2.80 9.20 3.16
16 5.15 2.49 6.97 2.65 9.38 3.16
TC - Total Capacity (kW)
IP - Input Power (kW)