uto OFF/ON button pressed
Test Run Operation
(Forced Cooling
Operation)
5 sec 5 sec
Test Run Operation
(Forced Heating
Operation)
beep beep 2x
Confirming mode notification sound
beep 3x
Remote Control
Receiver Checking
Mode
Stop
Auto OFF/ON button pressed
Auto OFF/ON button pressed Auto OFF/ON button pressed
Stop
Operation Time
Confirming mode
5 sec 5 sec
Auto Operation Stop
1 AUTO OPERATION MODE
The Auto operation will be activated immediately once the Auto OFF/ON button is pressed. This operation
can be used to operate air conditioner with limited function if remote control is misplaced or malfunction.
2 TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE)
The Test Run operation will be activated if the Auto OFF/ON button is pressed continuously for more than
5 seconds. A “beep” sound will heard at the fifth seconds, in order to identify the starting of Test Run
operation (Forced cooling operation). Within 5 minutes after Forced cooling operation start, the Auto OFF/ON
button is pressed for more than 5 seconds. A 2 “beep” sounds will heard at the fifth seconds, in order to
identify the starting of Forced heating operation.
In within 5 minutes after Forced heating operation start, the Auto OFF/ON button is pressed for more than
5 seconds. A confirming mode notification sound will be heard, in order to identify the starting Operation Time
Checking mode. (If less than 5 seconds pressed Auto OFF/ON button, Forced heating operation will be stop).
After that, in within 5 minutes after Operation Time Confirmation mode start, the Auto OFF/ON button is
pressed continuously for more than 5 seconds. A 3 "beep" sound will be heard at the fifth seconds, in order
to identify the starting Remote Control Receiver Checking mode. (If less than 5 seconds pressed Auto
OFF/ON button, Operation Time Confirmation mode will be continued).
The Auto OFF/ON button may be used together with remote control to set / change the advance setting of air
conditioner operation.
Auto Operation
uto OFF/ON button pressed
5 sec
Test Run Operation
(Forced Cooling
Operation)
8 sec 11 sec
Test Run Operation
(Forced Heating
Operation)
16 sec 21 sec 26 sec 36 sec
beep beep 2x
Setting Mode
beep 4xbeep 3x beep 4x
Main unit always continue Test Run (forced cooling) operation
Individual Processing
Mode
Operation Time
Confirming Mode
Cooling Operation
3 Notification sound
Stop receiving in operating status (LED : Light ON → Light OFF)
Receive the remote control reset code
Bee
Receive notification and diagnosis code
Refer failure diagnosis
function
Receive during the abnormal occurrence of protection operation (ON) Beep beep beep bleep
Receive the basic sound bit (after temperature SW is operated and when the temperature is upper
threshold and lower threshold)
bleep bleep
Operation receive, stop receive, set change, single function set (other than those above) bleep