168 
19.  Technical Data 
Technical data provided are based on the air conditioner running under free frequency. 
19.1  Cool Mode Performance Data 
Unit setting: Standard piping length, Hi Fan, Cool mode at 16°C 
Voltage: 230V 
19.1.1  CS-VZ9SKE CU-VZ9SKE  
 
Indoor (°C)  Outdoor DB (°C) 
DB  WB 
16  25  35 
TC  SHC  IP  TC  SHC  IP  TC  SHC  IP 
27 
19.0  2.99  2.66  0.24  2.81  2.53  0.33  2.50  2.40  0.43 
22.0  3.40  2.07  0.23  3.16  1.96  0.32  2.78  1.81  0.43 
23 
15.7  2.70  2.57  0.24  2.63  2.47  0.32  2.35  2.30  0.43 
18.4  3.05  2.04  0.22  2.80  1.93  0.31  2.59  1.78  0.42 
20 
13.3  2.18  2.14  0.23  2.11  2.07  0.32  1.85  1.81  0.42 
15.8  2.40  1.73  0.20  2.30  1.68  0.29  2.09  1.61  0.40 
 
19.1.2  CS-VZ12SKE CU-VZ12SKE  
 
Indoor (°C)  Outdoor DB (°C) 
DB  WB 
16  25  35 
TC  SHC  IP  TC  SHC  IP  TC  SHC  IP 
27 
19.0  4.186  3.726  0.446  3.93  3.54  0.606  3.50  3.36  0.800 
22.0  4.76  2.904  0.422  4.43  2.75  0.595  3.89  2.53  0.792 
23 
15.7  3.784  3.594  0.442  3.68  3.46  0.600  3.29  3.22  0.792 
18.4  4.271  2.862  0.412  3.92  2.70  0.582  3.62  2.50  0.780 
20 
13.3  3.056  2.995  0.433  2.95  2.89  0.588  2.59  2.54  0.776 
15.8  3.357  2.417  0.372  3.23  2.35  0.536  2.92  2.25  0.745 
 
TC   - Total Cooling Capacity (kW) 
SHC   - Sensible Heat Capacity (kW) 
IP   - Input Power (kW)