8.2. TEMPERATURE SHIFT
Once the operation starts, the remote control setting temperature will be shifted internally based on the setting fan speed and
outdoor air temperature. In addition, if Sleep Mode or Powerful Mode are set, the temperature shift will be carried out.
Setting of internal Setting Temperature
The internal setting temperature can be decided as follows:
8.2.1. Table a
Setting Temperature Shift based on outdoor air temperature.
1. Cooling, Soft Dry 2. Heating
8.2.2. Table b
Setting Temperature Shift based on fan speed.
Remote control setting fan speed Cooling Dry Heating
Lo +1.0°C +1.0°C +1.0°C
Me-, Me, Me+, Auto fan speed +1.0°C +1.0°C
Hi +1.0°C +1.0°C
8.2.3. Table c
Powerful Mode Shift
Cooling Dry Heating
Powerful -4.0°C -3.0°C +6.0°C