8.4.2. Deodorizing Control
·
This control is available during automatic fan speed for Cooling and Soft Dry Operation. It is not available during anti-freezing
control.
·
When the Thermostat ON operation, the deodorizing status starts from 1 → 2 → 3.
·
When the Thermostat OFF operation, the deodorizing status starts from 4 → 5 → 6 → 7.
·
If the Thermostat OFF operation after 3 minutes, the deodorizing status will start from 6.
8.4.3. Sensible Heat Control
·
This control is to improve the feeling in high fan speed during low Comp. Operation Frequency Command Number. When the
Comp. Operation Frequency Command Number is less than 4, the fan speed will reduce. When the Comp. Operation
Frequency Command Number is above 5 continuously for 5 minutes, the fan speed will resume to normal condition.
19