2.8. Counter / Parameter Auto Backup
The Counter Information can be backed up by installing an SD Memory Card into the SD Card Slot (CN70)
on the SC PC Board. This prevents losing Counter Information due to an error in the System Control (SC)
PC Board, or when replacing the SC PC Board.
The Parameter Auto Backup is the New feature for DP-C405 Series.
<Auto Backup>
The Machine backs up the F7 Counter, and Department Counter information into the SD Memory Card.
A. Every 4 hours, 6 times a day (3:55, 7:55, 11:55, 15:55, 19:55, and 23:55).
B. When turning the Power Switch on the Left Side of the machine to the OFF (DP-C405 Series).
1. Turn the Power Switch on the Left Side of the machine to the OFF ( ) position.
2. Install the SD Memory Card into the SD Card Slot (CN70) on the SC PCB. (Not into the Front Slot)
Refer to the Service Manual section 9.5.
3. Turn the Power Switch on the Left Side of the machine to the ON ( I ) position.
4. Set the Service Parameter “F5-179 Param/Cnt Auto Backup” to “Yes” (DP-C405 Series).
Set the Service Parameter “F5-179 Counter Backup” to “Yes” (DP-C354/C322 Series).
5. Reboot the machine by cycling the power. (Turn the Power Switch on the Left side of the machine to
the OFF ( ) then back to the ON ( I ) position.)
<Restore>
When the SC PC Board is replaced, the machine restores the Counter information from the backed up SD
Memory Card onto the new SC PCB.
1. Replace the SC PCB.
2. Turn the Power Switch on the Left Side of the machine to the ON ( I ) position.
3. Change the Service Parameter “F5-179 Param/Cnt Auto Backup” to “No” (DP-C405 Series).
Change the Service Parameter “F5-179 Counter Backup” to “No” (DP-C354/C322 Series).
4. Turn the Power Switch on the Left Side of the machine to the OFF ( ) position.
5. Remove the Backed up SD Memory Card from the replaced SC PCB.
6. Install this SD Memory Card into the SD Card Slot (CN70) on the new SC PCB.
7. Turn the Power Switch on the Left Side of the machine to the ON ( I ) position.
8. Perform the Service Parameter “F9-10 Param/Counter Restore”, and “00 SC Counter Restore” /
“02 Parameter Restore” (DP-C405 Series).
Perform the Service Parameter “F9-10 Counter Restore”, and “00 SC Counter Restore” (DP-C354/
C322 Series).
9. Set the Service Parameter “F5-179 Param/Cnt Auto Backup” to “Yes” (DP-C405 Series).
Set the Service Parameter “F5-179 Counter Backup” to “Yes”(DP-C354/C322 Series).
10. Reboot the machine by cycling the power. (Turn the Power Switch on the Left side of the machine to
the OFF ( ) then back to the ON ( I ) position.)
<Backup data>
The Counter information :
“F7-02 : Maintenance Count”, refer to Section 4.1.7. for additional details.
The Parameter information :
“Service Mode: F5/F6”, “Fax Service Mode 1” and “Check & Call”, refer to Section 4 for additional
details.
“User Parameter”, “Fax Parameter” and “Address Book”, refer to the Operation Instructions for
additional details.