81
FEB 2008Ver. 1.1
DP-C405/C305/C265
2.9. Counter / Parameter Backup to SD Card in the Front Slot
The Counter / Parameter Information can also be backed up by installing an SD Memory Card into the
Front SD Card Slot. This prevents losing the Counter / Parameter Information when replacing the SC/EC
PC Board (New feature for DP-C405 Series).
<Backup>
1. Install the SD Memory Card into the Front SD Card Slot.
2. Select the Service Parameter “F9-11 Param Backup to SD”, then select “Yes”.
3. After the parameters have been Backed up, press the “Stop” key.
4. Select the Service Parameter “F9-20 Counter Backup to SD”, and select “00 SC Counter Backup”
/ “01 EC Counter Backup”, then select “Yes”.
<Restore>
When the SC/EC PC Board is replaced, the machine restores the Counter / Parameter information from the
backed up SD Memory Card.
1. Replace the SC/EC PCB.
2. Turn the Power Switch on the Left Side of the machine to the ON ( I ) position.
3. Select the Service Parameter “9-12 Param Restore from SD”, then select “Yes”.
4. After the parameters have been restored, press the “Stop” key.
5. Select the Service Parameter “F9-21 Counter Restore From SD”, and select “00 SC Counter
Restore” / “01 EC Counter Restore”, then select “Yes”.
6. Reboot the machine by cycling the power. (Turn the Power Switch on the Left side of the machine to
the OFF ( ) then back to the ON ( I ) position.)