Home Return FP2 Positioning Unit
10-26
10.9 Special Mention
The time from the home input to the pulse output stop during the home return (home
search)
The FPPositioning unit performs the process in the very high speed, so that it starts counting the
number of the output pulses within 1µs from when the home input is ON. The time is always stable,
enabling the accurate home return (home search) operation. Since each axis is completely independent,
the home returns by the multiple axes at the same time are possible for the multiple-axis type.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic FPG Series and is the answer not in the manual?

Panasonic FPG Series Specifications

General IconGeneral
High-speed counterUp to 100 kHz
Input Voltage24 V DC
DimensionsVaries by model
WeightVaries by model
Program Capacity32 k steps
Programming LanguageLadder Logic
CommunicationRS232C, RS485, Ethernet
Pulse output100 kHz
Operating Temperature0 to 55 °C
Supply Voltage24V DC or 100-240V AC
Output TypeRelay, Transistor
Storage Temperature-20 to 70 °C
Humidity5 to 95% RH (non-condensing)