FP Positioning Unit Precautions Concerning the Operation and Programs
14-7
14.2 Precautions Concerning Practical Usage Methods
14.2.1 Setting the Acceleration/Deceleration to Zero
To initiate the target speed immediately without accelerating or decelerating (acceleration/deceleration
Zero operation = automatic startup operation), the startup speed and acceleration/deceleration time
should both be set to 0 (zero). This produces pulse output at the target speed, with an acceleration/
deceleration time of 0 (zero). Setting the startup speed equal to the target speed results in a set value
error, and the positioning unit will not start.