TEST AND MEASUREMENT
Issue 1 Section 6 MCUK990801C8
Revision 0 – 48 – Service Manual
16. Press [F6]. Go to, and select: "TRIM Other" again. Go to, and select: "BAT TEMP". Enter value from step 14 above.
Charging Calibration
17. For this procedure, set up the equipment as follows.
a. Connect 82 1W resistor between VBAT and Ground.
b. Connect PSU1 between VBAT and Ground, set to 3.7volts and switch on. (note that this gives 50mA)
c. Connect a second PSU (PSU2) to the phone via the phone's external connector. Set PSU2 to 5.8volts - current limit
set to 700mA.
18. Press {shift}+[F4].
19. Go to, and select: "Set DAC Data". Type a value of 714, [enter].
20. Using arrows ↑↓, highlight "Control out". Use ←→ arrows to highlight and select "CRG ON".
21. Disconnect VBAT by switching PSU1 output OFF.
22. Measure VBAT voltage at test battery. If the voltage is inside the range 4.1V±5mV then go to step 27 below. Otherwise,
calculate the difference thus:- (measured voltage - 4.2)/0.00616 = difference.
23. Press {shift}+[F4].
24. Go to, and select: "Set DAC Data". Enter value of:- (previously set value (which you originally set to 714)) - result from step
22 above (integer only).
25. Repeat steps 22 to 24 until measured voltage is 4.1V±5mV
26. If the final value for DAC Data is outside the range 7140 then there is a fault, and further investigation is required.
Otherwise store the value as described below.
27. Press [F6]; Go to, and select:- "Trim Other";
28. Go to, and select:- "DAC Reference"; Enter value.
29. Press {shift}+[F4].
30. Go to, and select:- "Set DAC Data".
31. Enter:- (value stored in step 28) - 200.
32. Press [F4].
33. Go to, and select:- View ADC lines.
34. Read value for ADIN1 ("BAT VOLT").
35. If ["BAT VOLT HIGH" (from step 5) - value read above], is inside the range 2142 then go to step 36 below to store
value. Otherwise there is a fault, and further investigation is required.
36. Press [N] (in repeat yes/no box), then [enter]. Press [F6]; Highlight and select "Trim Other".
37. Highlight and select "DAC Step".
38. Enter value obtained in step 35, above.
39. Press {shift}+[F4].
40. Select: "Set DAC Data".
41. Re-enter original value from step 26 (i.e. present value +200).
42. Press [F4].
43. Highlight, and select:- "View ADC Lines".
44. Read ADIN5 (CRG CURRENT) value and record it as "Total current".
45. Disconnect the 82 Resistor.
46. Press [Y], [enter] to read ADC value again, and record it as "Phone current".
47. "Charge current" = "Total current" - "Phone current". If this outside the range 44 then there is a fault, and further
investigation is required. Otherwise, calculate offset thus:- "Charging current" - 43 = Offset.
48. Press [N] (in repeat yes/no box), then [enter]. Press [F6]
49. Go to, and select:- "TRIM other".
50. Go to, and select:- "Complete offset".
51. Enter offset calculated above.
52. At the end of all tests, turn OFF power supplies and remove the phone.