Feature Guide References
1.26.1.2 Syslog Record Management
Syslog—Major
Selects whether to output major alarm information to a syslog server.
Value Range
Disable, Enable
Maintenance Console Location
13.1 [11-1] Main
Programming Manual References
None
Feature Guide References
1.26.1.2 Syslog Record Management
Syslog—Minor
Selects whether to output minor alarm information to a syslog server.
Value Range
Disable, Enable
Maintenance Console Location
13.1 [11-1] Main
Programming Manual References
None
Feature Guide References
1.26.1.2 Syslog Record Management
Remote
Remote—Analogue Remote (Modem) Floating Extension Number
Specifies the floating extension number for analogue remote maintenance. To enable this setting, an
RMT
card must be installed, and
Remote—Remote Programming on this screen must be enabled.
Value Range
Max. 5 digits (consisting of 0–9)