2.5.4.8 Host PBX Access Code (Access Code to the Telephone
Company from a Host PBX)
Description
This PBX can be installed behind an existing PBX (host PBX) by connecting the extension ports of the host
PBX to the trunk ports of this PBX (behind PBX). A Host PBX Access code is required for the behind PBX to
access the telephone company (e.g., to make outside calls) through the host PBX. The Trunk access number
of the host PBX should be stored as a Host PBX Access code on a trunk group of the behind PBX.
A preprogrammed Pause time will be automatically inserted between the user dialled Host PBX Access code
and the subsequent digits (2.5.4.7 Pause Insertion).
[Example]
Dials "9-0-01-23-4567".
Idle Line
Access No.
Telephone No.
Host PBX
Access Code
Outside Party
(01-23-4567)
Extn. 101 Extn. 102
TRG1
Telephone Company
Host PBX
PBX
Dials "9-101".
Idle Line
Access No.: 9
Idle Line
Access No.
Extn. No.
of the Host PBX
Dials "0-01-23-4567".
Host PBX
Access Code
Telephone
No.
Host PBX
Access Code: 0
Note
"0" should be assigned as a Host PBX Access code for trunk group (TRG) 1 of the behind PBX.
Conditions
TRS/Barring
104 Feature Guide
2.5.4 Trunk Call Features

Table of Contents

Other manuals for Panasonic KX-NS1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic KX-NS1000 and is the answer not in the manual?

Panasonic KX-NS1000 Specifications

General IconGeneral
TypeHybrid IP-PBX
Max Concurrent Calls256
VoIP ProtocolsSIP, H.323
Power SupplyAC 100-240V, 50/60Hz
Maximum Extensions1, 000
IP Extensions1000
Operating Temperature0°C to 40°C
Humidity10 to 90% (non-condensing)
Max Users1000