4.2.3.3 UM Group Failover
Description
Each UM group can be assigned a failover destination. If a call is routed to a UM group that is unavailable, the
call will be redirected to the specified UM group.
PBX PBX
UM Group 1
Failover Group: 3
UM Group 2
PBX
UM Group 3
Offline
Incoming Call
UM group failover applies to incoming trunk calls (including DISA), intercom calls, and faxes.
Conditions
If
a
call cannot be routed to a UM group and no failover UM group is specified, the system handles the call
according to Intercept Routing—No Destination (® 2.1.1.7 Intercept Routing—No Destination).
Failover redirection does not cascade; if the failover destination is unavailable, the call will not be redirected
to that UM group’s failover destination.
The same UM group may be specified as the failover destination for multiple UM groups. For example, UM
group 3 can be the failover destination for both UM group 1 and UM group 2.
PC Programming Manual References
11.7.2 PBX Configuration—[3-7-2] Group—UM Group—Unit Settings—
Fail Over Site Name
Feature Guide 371
4.2.3 One-look Networking Survivability

Table of Contents

Other manuals for Panasonic KX-NS1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic KX-NS1000 and is the answer not in the manual?

Panasonic KX-NS1000 Specifications