Loading...
Description Specifies whether the unit periodically checks for updates of
configuration files.
Value Range
Y (Enable periodic synchronization of configuration files)
N (Disable periodic synchronization of configuration files)
Default Value
N
Web User Interface Reference Cyclic Auto Resync (Page 125)
CFG_CYCLIC_INTVL
Value Format Integer
Description Specifies the interval, in minutes, between periodic checks for updates
of the configuration files.
Value Range 1–40320
Default Value 10080
Web User Interface Reference Resync Interval (Page 125)
CFG_RTRY_INTVL
Value Format Integer
Description Specifies the period of time, in minutes, that the unit will retry checking
for an update of the configuration files after a configuration file access
error has occurred.
Note
This setting is available only when "CFG_CYCLIC" is set to "Y".
Value Range 1–1440
Default Value 30
CFG_RESYNC_TIME
Value Format String
Description Specifies the time (hour:minute) that the unit checks for updates of
configuration files.
Document Version 2010-08 Administrator Guide 151