2. Press "STOP /-DEMO" button. A symbol of self-diagnostic is
indicated on the display if an error is found. If several errors are
found, a respective indication is displayed when "STOP /-
DEMO" button is pressing repeatedly. (e.g. H01 CD F15 F01)
If no error is found, only "T " indication is displayed and remains
unchange even if "STOP /-DEMO" button is pressed.
11.5. Displaying Self-Diagnostic Results
<Cassette Deck Section> (H01, H02, H03, F01, F02)
1. Enter the self-diagnostic mode, following the instructions
described in [11.2. Entering Self-Diagnostic Mode].
2. Insert a normal-positioned music tape with erase prevention
niches on both Sides A and B. Press [TAPE ] button to
activate the TPS operation so that the tape automatically stops at
an interval between music selections.
3. Press [STOP /-DEMO] and [TAPE ] buttons together on the
remote controller. (Recording does not start.)
4. Then, insert a Cr02-positioned blank cassette tape with an erase
prevention niche of Side A or B set to the left side.
5. Press [ /FF/ ] button. The tape will be forwarded and
automatically stop after two seconds.
6. Remove the cassette tape, and set the other side.
7. Press [ /REW/ ] button. The tape will be rewound and
automatically stops after two seconds.
8. Press [STOP /-DEMO] button on the unit.
If an error is found, a self-diagnostic key appears on the display.
If several errors are found, the display shows these keys when
[STOP /-DEMO] button is pressed repeatedly. (Ex.: H01 - H02 -
F01 - H01)
If no error is found, only the message, CD TEST” appears on the
display.