(*1) TPS operation (music search) detects the blank sections between music selections.
Therefore, do not use tapes with the following conditions:
- A blank section that lasts only 4 seconds or less.
- No blank sections (recording through microphones, etc.).
- Music selections that have extremely low pitches or prolonged
silent sections (such as classical music).
- and/or Music recorded with fade in/out effect.
11.5.1. Error detection for CD Block
Error Code Abnormal Items Possible Cause
F15 CD REST SW
abnormal
CD traverse position intial setting operation failsafe
counter
waiting for REST SW to turn on. Error No. shall be clear by
force
during coldstart.
H15 The CD tray closes CD disc tray detect switch NG. (Check and replace)
F26 CD servo LSI
command signal
abnormal
CD function DTMS command, after system setting, If
SENSE
cannot be detected. Memory shall contain F26 code. After
CD function shall continue, error shall occur “NO DISC”.
Error No. shall be clear by force or coldstart.
F28 DISC LOAD
abnormal
While going to play position, if failsafe counter is finished
and
o change or switch target condition was not achieve, this
error
be memorized. Next time mechanism operates, it shall do
coldstart.
Error No. shall be clear by force or coldstart.
F29 DISC unload
abnormal
While going to play position, if failsafe counter is finished
and
no change or switch target condition was not achieve, this
error
be memorized. Next time mechanism operates, it shall do
coldstart.
Error No. shall be clear by force or coldstart.
F27 Slide operation
abnormal
During vertical operation, if failsafe timer is finished and
switch
change or switch target condition was not achieve, this
error
memorized. Next time mechanism operates, it shall do
coldstart.Error
No. shall be clear by force or coldstart.
F17 Down SW abnormal During vertical operation going to the bottom position, if
failsafe
is finished and switch no change or switch target condition
was
achieve, this error shall be memorized. The Next time
mechanism
operates, it shall do mechanism initialization.Error No.
shall
by force or coldstart.
F22 Loading Mode /
Mecha abnormal
During mecha initialization, Loading mode mechanism
abnormal,
normal operation cannot be achieve. The next time
mechanism
operates, it shall do mechanism initialization.Error No.
shall
by force or coldstart.
Abnormal
item
Error Display Method of detection
F75 CD power abnormal Under normal operation (self-diagnostic mode inclusive),
check
CDRST is H for SELECTOR at CD. If it is not H after 1 sec, it
shall
memorised as an error.