How to use the terminals of the ALARM/CONTROL connector
This connector is used when connecting an external device such as a sensor that outputs alarm signals or when installing an
external alarm device such as a buzzer or a lamp. The connector to be used should be compatible with the pin array.
Pin array
The pin array is different from other Panasonic recorders. Make sure
that the connection is correct referring to the following.
Pin No. Signal Operation Remarks
1 Alarm input 1 Event action will be performed according to the
settings.
Non-voltage make contact, 5 V
pull-up/−100 mA
2 Alarm input 2
3 Alarm input 3
4 Alarm input 4
5 Alarm input 5
6 Alarm input 6
7 Alarm input 7
8 Alarm input 8
9 Alarm input 9
10 Network error output Signal output upon detection of a broken
Ethernet link
Open collector output, 24 V DC
max., –100 mA
11 Alarm reset input Canceling the alarm display Non-voltage make contact, 5 V
pull-up/−100 mA
12 N/A
13 Signal ground
14 Signal ground
15 Face matching output Signal output at the occurrence of a face match-
ing alarm
Open collector output, 24 V DC
max., –100 mA
16 HDD error output Signal output upon detection of an HDD error
17 Camera error output Signal output upon detection of a camera error
18 Recorder error output Signal output upon detection of a recorder error
19 Recording error output Signal output upon detection of a recording error
20 Time adjustment signal input According to the signal input from the other
device, the time of this recorder will be adjusted
to the hour (00 minutes 00 seconds).
Non-voltage make contact, 5 V
pull-up/−100 mA
21 Alarm output Alarm signal will be supplied at an event occur-
rence (Except for a face matching alarm)
Open collector output, 24 V DC
max., –100 mA
22 N/A
23 N/A
24 N/A
25 +5 V output +5 V output 200 mA max.
About the connector