[Authentication]
Set the user authentication method.
Digest or Basic: Uses “Digest or Basic” authentication.
Digest: Uses “Digest” authentication.
Basic: Uses “Basic” authentication.
Default: Digest or Basic
Note
When the [Authentication] setting has been changed, close the web browser, and then access the
camera again.
For other devices such as network disk recorders, unless otherwise stated, digest authentication is not
supported. (As of August, 2016)
[User name registration]
At the time of new registration, register a new user name in [User name]. Click [ ] in “User name
registration” to view registered users. Registered users are displayed as “Registered user name [Access
level]”. (Example: admin [1])
If you click the [Change] button on the right, the selected user will be displayed in [User name], and you can
change the password. By clicking the [Delete] button on the right, you can delete the selected user.
[User name]
Enter a user name.
Available number of characters: 1 - 32 characters
Unavailable characters: " & : ; \
Default: None (blank)
Note
When the user name already in use is entered and the [Set] button is clicked, the respective user
information will be overwritten.
[Password (8 to 32 characters)] [Retype password]
Enter a password.
Available number of characters: 8 - 32 characters
Unavailable characters: " &
Default: None (blank)
Note
Distinguish between upper- and lower cases.
For the password, use two or more types of characters from alphabetic characters, numbers, and
symbols.
[Access Level]
Select the access level of the user from the following.
1. Administrator: Allowed all available operations of the camera.
2. Camera control: Allowed to control the camera. Functions selected for “Access level” can be operated.
3. Live only: Allowed to display live view. Functions selected for “Access level” can be operated.
Default: 3. Live only
[Access level]
Select the available functions based on the user access level (camera control, live view, guest user).
Default:
Camera control: All are checked
Live only: All are not checked