640 Icon LCD Keypad 9n
5.0 Arming
When the system is armed, it will respond to any breach in the zones
according to the way each zone is programmed. For example, if
someone opens a window that is armed, the system can trigger an
alarm and alert your monitoring station.
5.1 Exit Delay Timer
Arming the system will start the Exit Delay Timer. This will provide
enough time for you to exit the protected area before the system
arms. The light and the appropriate arm icon will both flash during
the exit delay. Your installer can assign different time limits and
program the keypad to beep during the exit delay.
5.2 Regular Arming
This method is used for the everyday arming of the system. All zones
within the protected area must be closed to arm the system.
Use One-Touch keys (see Section 5.6 on page 12) or a
keyswitch to arm the area (see Section 5.7 on page 13).
How do I Regular arm the system?
1. Enter your [
ACCESS CODE]. Your keypad will emit a confirmation
beep. The functionality icons will illuminate.
2. Press the [] key.
3. If you have access to more than one area, press the number key
representing the area you want to arm, or press the [0] key for
all assigned areas. After the confirmation beep, the Exit Delay
Timer will begin. The Regular arm icon (or the affected area
numbers) will flash.
4. Once the system has armed, the Regular arm icon will
illuminate with the armed areas .
DGP2640_EU00.fm Page 9 Friday, April 8, 2005 11:28 AM