Magellan / Spectra SP 25
GSM Communication
Systems that include the PCS Series (GSM) can be programmed for GSM communication using the following sections:
* This option also applies to landline communication.
NOTE: To erase a phone number/numeric message, press the [SLEEP] key for each digit in the respective section.
PCS Series Programming
[800] Reporting
Option OFF ON
[8] Reporting*
Dialer activated Dialer deactivated
* This option also applies to landline communication.
Section Data
[815]* ___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/
MONITORING STATION TELEPHONE NUMBER 1
[816]* ___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/
MONITORING STATION TELEPHONE NUMBER 2
[817]* ___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/
BACKUP TELEPHONE NUMBER
[818]* ___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/
PAGER TELEPHONE NUMBER
[819]* ___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/
NUMERIC MESSAGE SENT WITH PAGER REPORTING
Special Keys for Telephone Numbers
Press Action or Value
[
OFF] *
[BYP] #
[
MEM] switch from pulse to tone dialing or vice versa
[TBL] 4-second pause
[SLEEP] deletes current digit
[] inserts blank space
[805] GSM Options
Option
[1] & [2]
[3] & [4] Future use
[5] & [6]
[7] Future use
OFF ON
[8] GSM RF jamming supervision
Disabled
Enabled
GSM Reporting
[1] [2] Primary Backup
OFF OFF Landline Landline
OFF ON Landline GSM
ON OFF GSM Landline
ON ON GSM GSM
GSM No Service Trouble Feedback
[5] [6]
OFF OFF Disabled
OFF ON Trouble only
ON OFF
When disarmed: Trouble only
When armed: Audible alarm
ON ON Silent alarm becomes audible alarm