F-2 December 1996 3610-A2-GB46-60
Table F-2
LADS Connection Distances for Models 3610
-
A4-xxx and 3611-B4-xxx
Wire Diameter (AWG)
Data Rate
(kbps)
19 Gauge
(.0359I or
.9122 mm)
22 Gauge
(.0253I or
.643 mm)
24 Gauge
(.0201I or
.51
1 mm)
26 Gauge
(.0159I or
.404 mm)
2.4 20.0
mi
(32.2 km)
16.6 mi
(26.7 km)
12.7 mi
(20.5 km)
9.4 mi
(15.1 km)
4.8
19.4 mi
(31.2 km)
12.7 mi
(20.5 km)
9.6 mi
(15.4 km)
7.1 mi
(11.5 km)
9.6
15.23 mi
(24.51 km)
10.18 mi
(16.39 km)
7.32mi
(11.77 km)
5.87 mi
(9.45 km)
19.2
12.91 mi
(20.78 km)
8.23 mi
(13.25 km)
5.89 mi
(9.49 km)
4.69 mi
(7.55 km)
38.4 1
1.2 mi
(18.0 km)
6.55 mi
(10.55 km)
4.79 mi
(7.71 km)
3.53mi
(5.68 km)
56
10.84 mi
(17.45 km)
6.4 mi
(10.3 km)
4.50 mi
7.24 km)
3.34 mi
(5.37 km)
64
10.69 mi
(17.2 km)
6.06 mi
(9.76 km)
4.47 mi
(7.2 km)
3.20 mi
(5.15 km)
Table F-3
(1 of 3)
General COMSPHERE 3600 Series Technical Specifications
Specifications Criteria
AC POWER FUSE
Model 3610/361
1 DSU
3000 Series Carrier
No accessible fuse
4-amp fuse for +115 Vac; Part number 190-0037-0431
(two spares supplied with carrier)
AC POWER REQUIREMENTS
3610 DSU
3610 DSU with DBM
3611 DSU
3611 DSU with DBM
3000 Series Carrier (16 DSUs with DBMs
plus SDU and fan module)
24 Vac (CT), 60 Hz +3 (0.093 amp, 8.0 watts at 115 Vac)
24 Vac (CT), 60 Hz +
3 (0.114 amp, 9.5 watts at 115 Vac)
24 Vac (CT), 60 Hz +
3 (0.029 amp, 4.5 watts at 115 Vac)
24 Vac (CT), 60 Hz +
3 (0.080 amp, 8.0 watts at 115 Vac)
90—132 Vac, 60 Hz +
3 (1.930 amp, 165 watts at 115 Vac)