Technical Specifications E-23
DC590+ DRV Series DC Digital Drive
Wire Sizes and Termination Tightening Torques (Frames 1, 2, 3, 4 & 5)
Control wiring must have a minimum cross-section area of 0.75mm
2
(18AWG)
UL EUROPE
Terminations
Maximum Tightening
Torque
Recommended Wire Size Maximum Terminal Aperture Size (AWG) Maximum Terminal Aperture Size (mm
2
)
All Units
A1 – A9, B1 – B9, C1 – C9 0.6-0.8Nm (5-7 lb-in.) 14 AWG 12 2.5
Frame 1 15A, 35A UNITS
A+, A- 1.8Nm (16 lb-in) 8-18 AWG 8 10
L1, L2, L3 1.8Nm (16 lb-in) 8-18 AWG 8 10
Grounding terminal 2.0Nm (17 lb-in.) 12 AWG - -
AUX. CONT. (TB4) 0.5Nm (5.0 lb-in) 12 AWG 12 2.5
F+, F- 0.8Nm (7.0 lb-in) 14 AWG 12 2.5
BL1, BL2, BL3 0.8Nm (7.0 lb-in) 12-22 AWG * 12 2.5
L, N, 3, 4, TH1, TH2 0.5Nm (5.0 lb-in) 12 AWG 12 2.5