Compax3F device description Hydraulics Controller
16
192-121100 N7 December 2010
3.2.4. Analog Input (plug X1)
Connector
X1 Pin
Descripti
on
Combicon 3.81mm; female
connector
1 24V Supply Sensor 0
2 GND Supply Sensor 0
3 IN0+ Signal Sensor 0 +
4 IN0- Signal Sensor 0 -
5 24V Supply Sensor 1
6 GND Supply Sensor 1
7 IN1 + Signal Sensor 1 +
8 IN1 - Signal Sensor 1 -
9 24V Supply Sensor 2
10 GND Supply Sensor 2
11 IN2 + Signal Sensor 2 +
12 IN2 - Signal Sensor 2 -
13 24V Supply Sensor 3
14 GND Supply Sensor 3
15 IN3 + Signal Sensor 3 +
16 IN3- Signal Sensor 3 -
17 IN4+ +/-10V Input 4
18 IN4- +/-10V Input 4
19 IN5+ +/-10V Input 5
20 IN5- +/-10V Input 5
Requirement: Connection cable
Use shielded cables.
Shield connection of the cables
The cable must be fully-screened and connected to the Compax3 housing. Use the
cable clamps/shield connecting terminals furnished with the device.
3.2.4.1 Wiring of the analog inputs
Input IN0
Input IN4
10pF
200K
200K
In0-
200K
X1/4
200K
In0+
X1/3
250
Compax3 Fluid
1nF
22.1K
100K
In4+
22.1K
X1/17
100K
1nF
In4-
X1/18
2
.5V
Compax3 Fluid
IN0 to IN3 do have the same wiring!
Pin assignment (see on page 16) X1
IIN4 and IN5 (X11/19 and X11/20) have the same
wiring!