Compax3F device description Hydraulics Controller
22
192-121100 N7 December 2010
3.2.10. Feedback (connector X13)
The following position sensors can be connected via X13:
1VSS SineCosine (max. 400Hz)
RS422 Encoder (max. 5MHz, (track A or B) or step/direction)
SSI (RS422)
Start / Stop (Time of Flight, RS422)
EnDat2.1
1. Feedback system / X13 High Density /Sub D
Pin
RS422 Encoder
SineCosine
1VSS
EnDat 2.1
Start/Stop
(time-of-flight)
SSI
1
+24V
max. 100mA
+24V
max. 100mA
2 Sense+ Sense+ Sense+
3
Sin+ Sin+
4
Vcc +5V (controlled
on the encoder side)
Vcc +5V (controlled
on the encoder
side)
Vcc +5V (controlled
on the encoder side)
5
+5V (for encoder)
max. 150mA
+5V +5V
6 A-
Clock- INIT- Clock-
7 A+
Clock+ INIT+ Clock+
8 B+ COS+ COS+ STSP+
9
SIN- SIN-
10
11 Sense- Sense- Sense-
12 B- COS- COS- STSP-
13 N- N- DATA-
DATA-
14 N+ N+ DATA+
DATA+
15 GND GND GND GND GND
Max. start/stop time is 1.6ms (over 4.15m).
Note on F12:
+5V (Pin 4) is measured and controlled directly at the end of the line via Sense -
and Sense +.
Maximum cable length: 100 m
Caution! Pin 4 and Pin 5 must under no circumstances be connected!
3.2.10.1 Connections of the encoder interface
10nF
+5V
121
A
1K
1
K
GND
A B N
RS422
Transceiver
B N
Compax3
The input connection is available in triple (for A & /A, B & /B, N & /N)