Parker EME
Technical Characteristics
192-121100 N7 December 2010
25
EMC limit values
EMC interference emission
Limit values according to EN 61000-6-4: 2001
for the industrial environment
EMC disturbance immunity
Limit values according to EN 61000-6-2: 2001
for the industrial environment
Environmental requirements Compax3F
General ambient conditions
In accordance with EN 60 721-3-1 to 3-3
Climate (temperature/humidity/barometric
pressure): Class 3K3
Permissible ambient temperature:
Operation
storage
transport
0 to +45 °C class 3K3
25 to +70 °C class 2K3
25 to +70 °C class 2K3
Tolerated humidity:
no condensation
Operation
storage
transport
<= 85% class 3K3
<= 95% class 2K3
<= 95% class 2K3
(Relative humidity)
Elevation of operating site
<=1000m above sea level for 100% load ratings
<=2000m above sea level for 1% / 100m power
reduction
please inquire for greater elevations
Mechanic resonances:
EN 60068-2-6 (sinusoidal excitation)
Sealing
Protection type IP20 in accordance with
EN 60 529
Insulation requirements
Degree of contamination
Level of contamination 2 according to EN 50 178
UL certification
Conform to UL:
USL according to UL508 (Listed)
CNL according to C22.2 No. 142-M1987.
(Listed)
Certified
E-File_No.: E198563
The UL certification is documented by a “UL” logo on the
device (type specification plate).
“UL” logo:
Detailed information on the technical data of the Compax3F devices can be
found in the Help-files of the individual Compax3F device types.