EasyManua.ls Logo

Parker Vansco - Power Control Digital Inputs

Parker Vansco
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Guide 23
Inputs
Active low input
The active-low input must be connected to ground to ensure there is a ground
connection when the state of the input changes.
The following shows a typical active-low digital input connection:
Internal to product
Application switch
Active Low
Digital Input
Figure 9: Active low digital input connections
3.2.2. Power Control Digital Inputs
The VMM2404 has 1 active high digital input dedicated to power control that is
used for waking up (turning on) the product, called POWER_CONTROL.
3.2.2.1. Power Control Digital Input Capabilities
The VMM2404 has an active high power control digital input that must be
activated to power up the VMM2404.
Note: The power control digital input voltage must be greater than 4.0 V
before it is considered an active high input.
The power control digital input wakes-up the VMM2404 when switched high to a
voltage of 4.0 V or greater, and puts the VMM2404 in sleep mode (turns it off)
when switched low to a voltage less than 1.7 V. The VMM2404 will also go into
sleep mode when an open circuit condition occurs on the power control digital
input.

Table of Contents