EasyManua.ls Logo

Parker Vansco - Addressing Digital Inputs

Parker Vansco
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Guide 25
Inputs
The following shows a typical power control digital input connection:
Internal to product
Power Control Input
Power
Control
Pull-Down
Resistor
Battery
Fuse Min.
200 mA
Application Switch
Figure 10: Power control digital input installation connections
3.2.3. Addressing Digital Inputs
The VMM2404 has 5 active low digital inputs that are used for module
addressing on the CAN network:
ADDR1 to ADDR5
3.2.3.1. Addressing Digital Input Capabilities
The following table provides specifications for the VMM2404 addressing digital
inputs:
Addressing Digital Input Specifications
Item
Min
Nom
Max
Unit
Input voltage range
0
-
32
V
Overvoltage
-
-
36
V
Pull-up resistance
9.8 k
-
10.2
Minimum negative going threshold
0.9
-
-
V
Maximum positive going threshold
-
-
2.15
V
Cutoff frequency (hardware)
-
80
-
Hz
De-bounce time
10
-
-
-
ms
Wetting current
316
-
343
uA
Leakage current sleep mode
- pin grounded or floating
-
0
-
A
10
De-bounce time for address inputs is based on hardware cutoff frequency. The software reads the address in succession
during power-up until it receives two consecutive results that are the same. The time between readings is in the microsecond
range so there is technically no software de-bounce on these inputs.