The following shows a typical power control digital input connection:
Internal to product
Power Control Input
Power
Control
Pull-Down
Resistor
Battery
Fuse Min.
200 mA
Application Switch
Figure 10: Power control digital input installation connections
3.2.3. Addressing Digital Inputs
The VMM2404 has 5 active low digital inputs that are used for module
addressing on the CAN network:
ADDR1 to ADDR5
3.2.3.1. Addressing Digital Input Capabilities
The following table provides specifications for the VMM2404 addressing digital
inputs:
Addressing Digital Input Specifications
Minimum negative going threshold
Maximum positive going threshold
Cutoff frequency (hardware)
Leakage current sleep mode
- pin grounded or floating
De-bounce time for address inputs is based on hardware cutoff frequency. The software reads the address in succession
during power-up until it receives two consecutive results that are the same. The time between readings is in the microsecond
range so there is technically no software de-bounce on these inputs.