24 VMM2404
Inputs
The following table provides specifications for the power control digital input:
Power Control Digital Input Specifications
Item
Min
Nom
Max
Unit
Input voltage range
0
-
32
V
Pull-down resistance
3.1 k
-
3.5 k
Ω
Minimum negative going threshold
2.14
-
-
V
Maximum positive going threshold
-
-
4.0
V
Power-up threshold
-
1.7
-
V
Cutoff frequency (hardware)
8
-
85
-
Hz
De-bounce time (software)
9
25
-
50
ms
Overvoltage
-
-
36
V
Wetting current @ 12 V
3.43
-
3.87
mA
Leakage current sleep mode
- battery @ 12 V
-
-
200
uA
3.2.2.2. Power Control Digital Input Installation Connections
You must be aware of the following when connecting the power control digital
input:
The power control digital input is usually connected to the vehicle ignition,
but it can be connected to any power source in a system.
To protect the harness that connects the VMM2404 to the ignition, place a
fuse of 200 mA or higher in the circuit that feeds the VMM2404.
If your VMM2404 must always be powered, the power control digital input
can be directly connected to a fused battery power input (called VBATT),
which will provide constant power.
When battery power (VBATT) is connected, and the power control digital
input is inactive, the VMM2404 will go into sleep mode.
8
Assumes there is a zero ohm source impedance from driving source. The actual cutoff in the application will be partially
determined from the source impedance and VMM input capacitance.
9
De-bounce time is based on a sampling rate of 40 Hz.