Installer manual Fleck 2850 SXT - Programming
Ref. MKT-IM-030 / C - 12.05.2020 53 / 104
6.5.1 Master programming mode chart
Parameter Options Definition Note
DF Display format GAL US units -
Ltr Metric units -
RF Regeneration
flow
dF1b Std DF single
backwash
Standard for 9000 Twin valve
dF2b Std DF double
backwash
-
FLtr Filter To be used with standard piston only.
UFbd UF brine first -
UFlt UF filter To be used with UF piston only.
Othr Other -
CT Regeneration
control type
Fd Metered delayed -
FI Metered
immediate
Standard for 9000 Twin valve
tc Time clock -
dAY Day of the week -
NT Number of
tanks
1 Single tank
system
-
2 Double tanks
system
-
TS Tank in service U1 Tank1 in service Only displayed for double tanks
system.
U2 Tank2 in service
C Unit capacity 0.1 to
9’999’000
°TH*m
3
Only displayed for volumetric
regenerations.
V Filter capacity 1 to 999’900 L Only displayed for filter.
H Feedwater
hardness
1 to 1990 °TH, ppm or
grains
Only displayed for volumetric
regenerations.
RS Reserve
selection
SF Safety factor -
rc Fixed reserve
capacity
-
SF Safety factor 0 to 50 % Only available if set in reserve
selection.
RC Fixed reserve
capacity
0 to 50 % Only displayed for volumetric
regenerations and if set in reserve
selection.
DO Days override 0 to 99 Day -
RT Regeneration
time
00:00:00 to
23:59:59
Hour Regeneration time will not appear
unless regeneration day override is
on.