Installer manual Fleck 2850 SXT - Programming
60 / 104 Ref. MKT-IM-030 / C - 12.05.2020
1. Press or to set the current day.
2. Press to validate the selection and move to the next parameter.
6.5.16 Flow meter type (FM)
Select the flow meter type.
Options:
P0.7: ¾" paddle wheel meter (Standard setting for 4600, 5600 and 9100);
t0.7: ¾" turbine meter;
P1.0: 1" paddle wheel meter (Standard setting for 2750 and 9000);
t1.0: 1" turbine meter;
P1.5: 1½" paddle wheel meter (Standard setting for 2850);
t1.5: 1½" turbine meter;
P2.0: 2" paddle wheel meter;
Gen: generic or other non-Fleck meter.
1. Press or to set the flow meter type.
2. Press to validate the selection and move to the next parameter or exit
master programming mode and save modifications done.