EasyManua.ls Logo

Pentair FLECK 2850 SXT - Description; Technical Specifications

Pentair FLECK 2850 SXT
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer manual Fleck 2850 SXT - Description
Ref. MKT-IM-030 / C - 12.05.2020 15 / 104
3 Description
3.1 Technical specifications
Design specifications/ratings
Valve body Brass
Rubber components EP or EPDM
Weight (valve with controller) 4.6 kg (max)
Recommended operating pressure 1.8 - 8.6 bar
Maximum inlet pressure 8.6 bar
Hydrostatic test pressure 20 bar
Water temperature std 1 - 43°C
Water temperature for HW volumetric 1 - 65°C
Water temperature for HW time clock 1 - 82°C
Ambient temperature 5 -40°C
Regeneration flow DF
Bypass of raw water during
regeneration:
Standard Yes
NBP version No
Flow rates (3.5 bar inlet - valve only - top mount)
Continuous service flow (Δp=1bar) 11.6 m
3
/h
Peak service flow (Δp=1.8bar) 15.0 m
3
/h
Cv* 13.2gpm
Kv* 11.4m
3
/h
Maximum backwash flow
(Δp=1.8bar)
11.1 m
3
/h
*Cv: Flow rate in gpm across the valve at a pressure drop of 1 psi at 60°F.
*Kv: Flow rate in m
3
/h across the valve at a pressure drop of 1 bar at 16°C.
Valve connections
Tank top mounted adapter 4” – 8 UN
Inlet/Outlet 1½" BSP female
Riser tube 50 mm [DN40]
Drain line 1" NPT
Brine line (1600/1650) ⅜"
Brine line (1700/1710) ½”

Table of Contents

Other manuals for Pentair FLECK 2850 SXT