INTELLICHEM
®
Controller Installation and User’s Guide
INTELLICHEM
®
Controller Installation and User’s Guide
23
Hardware
To access the hardware menu: Press MENU Configuration Hardware
Most common hardware configurations can be selected by using the Auto Setup Wizard.
This menu allow more complex and custom settings.Use the Hardware menu to configure
IntelliChem for the pH and ORP hardware controls and dose being used. Upon entering
the hardware setup menu, all dosing will pause until the hardware setup is completed.
Factory Reset: Clear all calibrated values and run Auto Setup to initialize IntelliChem. For
Factory Default Settings.
Self Test Sequence: Upon entering a self test sequence, all dosing will pause until
the test is completed. Follow the on-screen prompts. “PASSED” indicates the test was
successful. See Troubleshooting section for error conditions, on page 46.
Doser Type 1/2: Select the pH Control Dose Type:
- IntelliChem pH feed method being used (INTERNAL PUMP, EXTERNAL
RELAY, CO2 EXT/RELAY (Carbon dioxide tanks), NONE.
Doser Type 2/2:
- INTERNAL PUMP: Right, MTR_R, Left, MTR_L
- EXTERNAL RELAY: Ex_Relay 1, Ex_Relay 2
- CO2 EXTERNAL RELAY: Ex_Relay 1, Ex_Relay 2
Flow (Rate) 2/2:
- INTERNAL PUMP (MTR_R/MTR_L): FLOW: 65 GPD (gallons per day).
- EXTERNAL RELAY 1 or 2: RATE: xxx GPD (gallons per day). Note: Set
to 0 to use time-based feed instead of volumetric (only on the Ext Relays
(not internal motors).
- CO2 EXTERNAL RELAY 1 or 2: Use Time (0) or SCFH (1-400).
pH Control (page 1/2 - 2/2)
Status Codes: This displays a complex series of values that indicate the real-time status
and alarm conditions.
Top line, Codes: HA= is the automation Home Address that IntelliChem has locked onto.
In the upper-right corner,
R0,1,2,4 which represents the UOC comm status.
R0 = standalone (no KA from Automation since power up)
R1 = Found KA packets within 30 seconds of power up
R2 = Found KA packets later, after 30 seconds, so was operating in standalone for a while
R4= Was in Automation mode (sending IntelliChlor commands through IntelliTouch) but
has dropped the connection.
The two-digit number (0-99) directly below the R# is the number of seconds it’s gone
without a valid KA packet. It should generally be 00-04 seconds. More than that means
that IntelliChem is missing the automation KA packets.
Note: Status and Alarm hexadecimal displayed codes represent the current IntelliChem
status. For further information, contact Technical Support (800) 831-7133.
Dosing will
resume when you
_exit this menu_
Press any button
After pressing the Hardware
button the following message is
displayed.
Configuration Menu (Continued)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair intellichem and is the answer not in the manual?

Pentair intellichem Specifications

General IconGeneral
pH ControlYes
ORP ControlYes
DisplayLCD
Waterproof EnclosureYes
Enclosure RatingNEMA 4X
AlarmsYes
Operating Temperature32° to 122°F (0° to 50°C)
Humidity Range0% to 95% non-condensing
CommunicationRS-485
OutputsRelays for chemical feed pumps
InputsFlow sensor