2
IntelliChlor User’s Guide
Electrolytic Cell Controller
The electrolytic cell controller includes a control panel with buttons and LED indicators to fully control and
produce chlorine. The cell controller measures the water temperature and salt level to optimally produce chlorine.
If the salt level is too low (red on salt display), the cell is turned off until salt is added to the pool. The controller
has a self-cleaning cycle which reverses the cell polarity, reducing calcium buildup. This feature turns the cell on
and off at regular intervals to prevent calcium and scale buildup and further maximizes cell life.
The electrolytic cell contains the control Salts and bipolar electrodes that perform the electrolysis and produce
chlorine when energized with DC current. Chlorine is generated as pool water containing salt passes through the
cell. The chlorine production can be varied by either adjusting the sanitizer output level on the cell or by varying
the number of hours IntelliChlor is on each day. IntelliChlor automatically cleans the IntelliChlor cell
electrodes once every few hours. This does not interrupt the production of Chlorine.
The cell also contains a mechanical flow sensor to ensure the proper amount of water is passing through the
cell to allow chlorination to occur. The cell automatically measures the water salinity and temperature and
displays on the top of the cell using lights. The cell includes a 4.57 meters (15 ft) UL approved four conductor
6 gauge “Type Z” cable for connection to the Power Center.
Flow Sensor: A cell flow sensor assures that there will always be adequate water flow through the cell
no matter how it is plumbed.
Temperature Sensor: To protect the unit from operation and potential damage, when the
temperature of the water falls below 15° C (59° F), the temperature sensor switches the unit off
Salt Sensor: Two salt sensor probes extend into the cell chamber and are activated upon startup of the
system and/or every 24 hours of running. Upon start-up, the salt sensor flashes for two minutes to
indicate it is in analysis mode, then determines the salt level and displays it.
Control Panel
status LEDs
Clear sliding
cover
MORE and LESS
output buttons
IntelliChlor Cell Assembly

Table of Contents

Other manuals for Pentair IntelliChlor IC20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair IntelliChlor IC20 and is the answer not in the manual?

Pentair IntelliChlor IC20 Specifications

General IconGeneral
ModelIntelliChlor IC20
TypeSalt Chlorine Generator
Pool SizeUp to 20, 000 gallons
Voltage120/240 VAC
Power SupplyExternal Power Center
Flow RateMinimum 20 GPM
Water Temperature50°F to 104°F (10°C to 40°C)
Cell Life10, 000 hours
Warranty3 years
Chlorine Output0.7 lbs/day