IntelliChlor User’s Guide
Connecting to the IntelliTouch Load Center
To connect the four wire cable from the IntelliChlor Power Center to the Personality board located in the
IntelliTouch Load Center:
WARNING Switch OFF main system power to the Load Center before making any connections.
1. Unlatch the Load Center enclosure door spring latches, and open the door.
2. Loosen the two retaining screws from the Outdoor Control Panel.
3. Lower down the Outdoor Control Panel on its hinges to access the Personality board located behind
the Outdoor Control Panel.
Retaining screws
Personality board
Outdoor Control Panel
Route wire from
IntelliChlor into
conduit knockout up
through raceway to
Personality board
IntelliTouch Load Center

Table of Contents

Other manuals for Pentair IntelliChlor IC20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair IntelliChlor IC20 and is the answer not in the manual?

Pentair IntelliChlor IC20 Specifications

General IconGeneral
ModelIntelliChlor IC20
TypeSalt Chlorine Generator
Pool SizeUp to 20, 000 gallons
Voltage120/240 VAC
Power SupplyExternal Power Center
Flow RateMinimum 20 GPM
Water Temperature50°F to 104°F (10°C to 40°C)
Cell Life10, 000 hours
Warranty3 years
Chlorine Output0.7 lbs/day