23
IntelliChlor User’s Guide
4. Route the four conductor cable up through the low voltage raceway in the Load Center to the
Personality board.
5. Strip back the cable conductors 6.35 mm (¼ in.). Insert the wires into the screw terminals (provided
in the kit). Secure the wires with the screws. Make sure to match the color coding of the wires; Red
= +15, Yellow = +DT, Green = -DT, and GND = Black.
6. Insert the cable plug onto either of the COMPORTS (J7 or J8) connectors located on the left side of
the Personality board.
7. When the connection has been completed, close the control panel into its original position and secure
it with the two retaining screws.
Personality board (left side)
8. Close the Load Center front door. Fasten the two spring latches