6
IntelliChlor User’s Guide
Operator Control Panel (continued)
Sanitizer Output LED Indicators
The five LED indicators display as a bar graph to show in 20% increments, the amount of time the chlorine is
produced per hour. In BOOST mode, these LEDs scroll in a pattern.
Note: If no LEDs are lit
0%
No LEDs on indicate no chlorine produced - IntelliChlor is off
20%
Produces chlorine 20% of the hour, 12 minutes on, 48 minutes off
40%
Produces chlorine 40% of the hour, 24 minutes on, 36 minutes off
60%
Produces chlorine 60% of the hour, 36 minutes on, 24 minutes off
80%
Produces chlorine 80% of the hour, 48 minutes on, 12 minutes off
100% Produces chlorine 100% of the hour, 59 minutes on, 1 minute off
Control Buttons
The More and Less buttons control the sanitizing cycle as displayed by the sanitizer output display bar graph
Slide the panel cover up to access the More, Less and Boost On/Off buttons.
More
Increases the time the cell produces chlorine, in 20% increments. Press and hold
this button to access the “System Status” mode to display the current usage
hours. For more information, refer to “Cell Usage Hours Meter,” on page 10.
Example: The Sanitizer Output display is showing 20%. Pressing the
More
button will turn off the 20% light and turn on the 40% light. The unit
will now produce chlorine 40% of the hour.
Less
Decreases the time the cell produces chlorine, in 20% increments.
Example: The Sanitizer Output display is showing 40%. Pressing the
Less
button will turn off the 40% light and turn on the 20% light. The unit
will now produce chlorine 20% of the hour.
Boost On/Off
Press and hold both the
More
and
Less
buttons activates Boost mode. Boost
mode sets the sanitizer output to run 100% for 24 hours straight. If the time clock
switches off the pump cycle, then switches power back on the next day, Boost
mode will continue until 24 hours has elapsed or Boost mode is canceled by the
user. The Sanitizer Output display will show a pattern LED display to indicate
Boost mode. To exit
Boost
mode, press and hold both the
More
and
Less
buttons.
Self Cleaning (reverse)
The unit has a self-cleaning feature that reduces scale buildup on the cell blades. The self-cleaning cycle tends
to reduce cell life, so less often is better, however, it is important to minimize the scale build-up on the blades.
The cycle can be every 2, 4, 6, 8, or 10 hours. It is factory set to two hours for the first 30 days of operation,
and then four hours thereafter. To change the self-cleaning cycle, press and hold the Less button for three
seconds. The sanitizer output display will now correspond to the self-clean cycle. Pressing More or Less
button will change this setting.
Example: The self-clean cycle is set to four hours and needs to be two hours. Press and hold the Less button
for three seconds. The sanitizer output will blink, then light up the 40% LED light only, indicating four hours.
If no button is pressed for five seconds, the display will return to the sanitizer output display. Pressing the Less
button within five seconds will now light the 20% LED light, indicating it is now at two hour self-clean cycle. Wait
five seconds and this mode will end, returning to the sanitizer output display.

Table of Contents

Other manuals for Pentair IntelliChlor IC20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair IntelliChlor IC20 and is the answer not in the manual?

Pentair IntelliChlor IC20 Specifications

General IconGeneral
ModelIntelliChlor IC20
TypeSalt Chlorine Generator
Pool SizeUp to 20, 000 gallons
Voltage120/240 VAC
Power SupplyExternal Power Center
Flow RateMinimum 20 GPM
Water Temperature50°F to 104°F (10°C to 40°C)
Cell Life10, 000 hours
Warranty3 years
Chlorine Output0.7 lbs/day