enhanced buffered fixcode (EF)
Command:
Response:
The R/W head makes attempts until successful to read a read only code. Only data that
changes is transferred via the interface, i.e. the R/W head transfers data whenever it reads a
new read/write tag or whenever it reads a read/write tag where there was previously no
read/write head within the detection range.
The status '05h' (read command) is output whenever a read/write tag leaves the detection
range.
The length of the read only code that is output depends on the tag type. See table "Supported
Tag Ty pe s " on p a g e 6 0 .
Byte Contents Bit no.
7 6 5 4 3 2 1 0
Byte 0
1)
Telegram length, high byte 0 0 0 0 0 0 0 0
Byte 1
1)
Telegram length, low byte 0 0 0 0 0 1 0 0
Byte 2 Command code (1Dh) 0 0 0 1 1 1 0 1
Byte 3 Reserved/Channel/Toggle bit 0 0 0 0 <Channel> <T>
1)
This byte is only used with the TCP/IP and MODBUS TCP/IP protocol.
Byte Contents Bit no.
7 6 5 4 3 2 1 0
Byte 0
1)
Telegram length, high byte 0 0 0 0 0 0 0 0
Byte 1
1)
Telegram length, low byte 0 0 0 0 1 0 1
1
2)
Byte 2 Command code (1Dh) 0 0 0 1 1 1 0 1
Byte 3 Reserved/Channel/Toggle bit 0 0 0 0 <Channel> <T>
Byte 4 Status <Status>
Byte 5 Reply counter <ReplyCounter>
Byte 6 ID code 00h ... FFh <ID-Code>
Byte 7 ID code 00h ... FFh <ID-Code>
... ID code 00h ... FFh <ID-Code>
Byte N
3)
ID code 00h ... FFh <ID-Code>
1)
This byte is only used with the TCP/IP and MODBUS TCP/IP protocol.
2)
The telegram length depends on the read only code length of the tag.
3)
N = <FixLen> + 5; Ethernet/IP: N = <FixLen> + 3