IPV
®
-2C
USER MANUAL
TRUE-IPV
®
THERAPY DEVICES
EN

Table of Contents

Questions and Answers

  • S
    Stephanie JonesAug 4, 2025
    What to do if my Percussionaire IPV-2C has no percussions?
    • P
      Patricia HaleAug 4, 2025
      If your Percussionaire Medical Equipment isn't producing percussions, first ensure that the inlet gas source is connected and the MASTER switch is in the ON position. Also, check the REMOTE connector for any blockages and inspect the Operational Pressure regulator. If these steps don't resolve the issue, it may require connecting to a gas source or replacing/repairing the MASTER switch. Service may be required.
  • K
    Kenneth RiveraAug 11, 2025
    Why is there no pressure indication on the Operational Pressure gauge of my Percussionaire Medical Equipment?
    • S
      sophiathomasAug 11, 2025
      If there is no pressure indication on the Operational Pressure gauge of your Percussionaire Medical Equipment, verify the inlet gas source and rotate the Operational Pressure knob clockwise until 40 psi is indicated. Ensure the MASTER switch is ON. If the problem persists, connect to a gas source and service may be required. Consider replacing or repairing the MASTER switch.
  • S
    Stephen BrownAug 16, 2025
    How to fix a Percussionaire IPV-2C nebulizer that is not aerosolizing?
    • C
      cwalkerAug 16, 2025
      If the nebulizer on your Percussionaire Medical Equipment is not aerosolizing, disconnect the yellow tubing from the IPV®-2C to verify constant flow. Check both yellow tubing connections and inspect the nebulizer bowl for flow out of the nebulizer baffle (Phasitron® 5 diagram). If there's no flow from the aerosol connector, service may be required. Reconnect the yellow connections and clean or replace the Phasitron® 5.
  • T
    Thomas TorresAug 22, 2025
    What to do if there is no display on the PDM of my Percussionaire IPV-2C?
    • L
      Lisa KellyAug 22, 2025
      If there is no display on the PDM of your Percussionaire Medical Equipment, check the battery orientation and strength. Also, check both tubing connections and ensure the Phasitron® 5 patient port is not occluded and is connected to the patient, if necessary. Replace the batteries if needed and reconnect any red connections. If not connected to a patient, occlude the patient end of Phasitron® 5.
  • B
    barbaracoleAug 29, 2025
    Why is the percussion rate slow on my Percussionaire IPV-2C?
    • L
      Lauren SmithAug 29, 2025
      If your Percussionaire Medical Equipment has a slow percussion rate, check the REMOTE connector for any external blockages. Ensure the percussion knob can change the rate. Rotate the percussion knob counterclockwise. Service may be required.

Summary

Chapter 1: Introduction

IPV Therapy Overview

Overview of IPV® therapy and the IPV®-2C device, detailing its function and benefits.

Three Components and Effects of TRUE-IPV

Describes the three components of TRUE-IPV® therapy and its physiological effects on the lungs.

TRUE-IPV Lung Recruitment Protocol

Illustrates the typical TRUE-IPV® lung recruitment protocol, explaining the process and physiological mechanisms involved.

Chapter 2: Intended Use

Indications and Patient Population

Specifies the indications for IPV®-2C use and the patient populations it is suitable for.

Contraindications and Adverse Reactions

Lists absolute/relative contraindications and possible adverse reactions associated with IPV® therapy.

Clinical Limitations and Document Symbols

Details clinical limitations, restrictions, and explains the various document symbols used in the manual.

Chapter 3: TRUE-IPV In-Line Valve with Ventilator

In-Line Valve Use and Treatment Frequency

Describes the intended use of the TRUE-IPV® In-Line Valve with ventilators and guidelines for treatment frequency.

Chapter 4: Setup

IPV-2 C and Stand Setup

Provides instructions for setting up the IPV®-2C device and its associated stand, including bracket placement.

Gas Connections and Pole Mount Options

Details rear panel connections, gas/air connector types, and pole mounting options for the IPV®-2C.

Phasitron5 Breathing Circuit Setup

Explains how to set up the Phasitron®5 breathing circuit, its unique venturi mechanism, and its role in TRUE-IPV® therapy.

Phasitron5 Diagram and Configurations

Illustrates the components of the Phasitron®5 and describes different configurations for patient use.

Connecting IPV-2 C and Phasitron5

Provides step-by-step instructions for connecting the IPV®-2C to the tubing harness and the Phasitron®5.

Adding Saline Solution or Medication

Details the procedure for adding saline or prescribed medication to the nebulizer bowl, with associated cautions.

In-Line Valve and Phasitron5 Integration

Guides on setting up the TRUE-IPV® In-Line Valve and adding the Phasitron®5 to it for therapy delivery.

Chapter 5: Controller Functions

PDM Setup

Details the setup process for the Percussionaire Digital Multimeter (PDM), including battery installation and initial checks.

Control Knobs Description

Explains the functions of the Demand CPAP/PEEP, Inspiratory Time, Inspiratory Flow, and Frequency control knobs.

Additional Controls: Manual Inspiration, Nebulizer, and Operational Pressure

Describes the Manual Inspiration button, Nebulizer switch, and Operational Pressure knob.

PDM POST and System Information

Details the Power-On Self-Test (POST) mode and the System Information display of the PDM.

PDM Wake and Active Modes

Explains the Wake and Active modes of the PDM, including display metrics and session timer functionality.

PDM Active Mode Display Details

Provides further details on the Active mode display, including Pulse Amplitude, Mean Airway Pressure, and Pulse Frequency Rate.

PDM Report and Sleep Modes

Describes the Report mode and the transition to Sleep mode, including session timer and system information display.

PDM Sleep and Fault Modes

Explains the Sleep mode and the Fault mode, including error messages and system failure indicators.

PDM Fault Logging and Detection

Details how the PDM logs hardware and software faults and the mechanisms for fault detection.

Chapter 6: Pre-Use Check

Pre-Use Check with Blender

Procedure for performing a pre-use check when using a blender.

Standard Pre-Use Check Procedure

Step-by-step guide for performing the standard pre-use check of the equipment.

Chapter 7: TRUE-IPV Therapy Parameters

Choosing Therapy Parameters

Factors influencing the choice of therapy parameters, including pathology, ventilation, clinical conditions, tolerance, and chest wiggle.

Proximal Pressure Variation Factors

Factors affecting proximal pressure variation, such as installed parameters, interface resistance, and patient characteristics.

Chapter 8: General TRUE-IPV Therapy Protocol

Pediatric;Adult Therapy Protocol

Step-by-step guide for administering TRUE-IPV® therapy to pediatric and adult patients.

Neonatal Therapy Protocol

Specific protocol for administering TRUE-IPV® therapy to neonatal patients, including positioning and monitoring.

Chapter 9: Cleaning and Disinfection

IPV-2 C and Stand Cleaning

Instructions for cleaning the IPV®-2C device and stand according to institutional protocols.

PDM and Phasitron5 Cleaning Procedures

Procedures for cleaning the Percussionaire Digital Multimeter (PDM) and the Phasitron®5 breathing circuit.

Phasitron5 Disassembly

Step-by-step guide on how to disassemble the Phasitron®5 for cleaning and maintenance.

Phasitron5 Cleaning Solutions and Methods

Details the cleaning steps for the Phasitron®5 and lists compatible cleaning and disinfecting solutions.

Chapter 10: Troubleshooting

Troubleshooting Common Problems

Provides a table to diagnose and resolve common issues related to pressure, percussions, and nebulizer function.

Changing PDM Batteries

Instructions on how to replace the batteries in the Percussionaire Digital Multimeter (PDM).

Chapter 11: Technical Specifications

IPV-2 C Specifications

Lists the technical specifications for the IPV®-2C device, including dimensions, weight, operating range, and performance.

Phasitron5 and PDM Specifications

Provides technical specifications for the Phasitron®5 breathing circuit and the Percussionaire Digital Multimeter (PDM).

Chapter 12: Service and Repair

Preventive Maintenance and Overhaul

Recommends annual preventive maintenance and mandated overhauls for the device, outlining factory services.

Chapter 13: Disposal of Equipment

Proper Disposal Procedures

Guidelines for the disposal of the IPV®-2C unit at the end of its useful life.

Chapter 14: Limited Warranty

Warranty Terms and Conditions

Outlines the warranty period, coverage, and exclusions for the IPV®-2C device.

Percussionaire IPV-2C Specifications

General IconGeneral
ModelIPV-2C
Operating Pressure50 psi
WeightApproximately 5 lbs
ManufacturerPercussionaire
Frequency Range100-300 cycles per minute
Intended UseAirway clearance and ventilation
Gas SourceOxygen or Air