P40 ED Input
35
Group
Parameter
Description
Machine type
User level
Setting range
Set value
1
199 Speed for light barrier compensating
stitches
1, 2, 3, 4, 5 B 300 - 2000 1200
2
203 Speed for seam program
ON = variable (pedal-controlled)
OFF = constant
1, 2, 3, 4, 5 B ON - OFF ON
206 Interrupt /stop seam sector at fi xed
speed
ON = with pedal -2,
OFF = with pedal 0
1, 2, 3, 4, 5 B ON - OFF OFF
3
301 Start voltage of solenoid for feed
changeover
ON = 24 V,
OFF = 32 V
1, 2, 3, 4, 5 C ON - OFF OFF
311 Stop stitch counting
ON = with thread trimming
OFF = without thread trimming
1, 2, 3, 4, 5 B ON - OFF ON
313 Programs as tack programs 1, 2, 3, 4, 5 B ON - OFF OFF
356 Input E4 is:
ON = Presser foot
OFF = suction
1, 2, 3, 4, 5 B ON - OFF ON
364 Feed adjustment means
ON = tack,
OFF = condensed stitches
1, 2, 3
4, 5
B
B
ON - OFF
ON - OFF
ON
OFF
382 Switch shaft of analogue input for
thread monitor
ON = quadruple,
OFF = double
1, 2, 3, 4, 5 B 0 - 100 15
387 Output motor operation activated
ON = with pedal = 1D (motor running)
OFF = with pedal = 1 (lower presser foot)
1, 2, 3, 4, 5 B ON - OFF ON
391 Speed for single stitch 4
5
1, 2, 3
B
B
B
200 - 700
200 - 700
-
450
600
-