Service functions
56
10 Service functions
10
.01 Reset / Cold start
After selecting the Reset menu, by pressing the relevant plus key it is possible to delete
seam parameters and seam programs or to carry out a cold start.
Press and hold plus-minus keys "A+" and "D+" and switch on the machine. ●
A+
D+
1 = Reset seam parameters
Press plus key "A+". ●
All seam parameters are deleted, the message "MASTER-RESET 1" appears briefl y
on the display.
2 = Reset seam programs
Press plus key "B+". ●
All seam programs are deleted, the message "MASTER-RESET 2" appears briefl y on the
display.
3 = Cold start
Press plus key "D+". ●
The values of the machine control unit, except the machine class, are set back to their
basic values. The message "COLD START" appears briefl y on the display.
After the cold start all programmed values are set back to their status at the
time of delivery. For this reason, after a cold start the parameters 799, 800 and
700 must by checked and reset if necessary.
A+
D+
B+
Select Reset