15.2 Mounting the Viewnder Mask on a Hasselblad V Series Camera
The image area of a Hasselblad V camera body at approx. 6x6cm is a dierent
size to the three IQ model’s sensors so it is necessary to insert a viewnder
mask.
There are two dierent masks available for Hasselblad V series cameras
according to which IQ is being used. The size IQ180 and IQ60 models CCD is
53.9x40.4 mm while the IQ140’s CCD measures 43.9x32.9mm. Please check
page 129 for the relevant viewnder mask.
Insert a Viewnder Mask
1. Remove the protection tape from the mask.
2. Dismount the waist-level nder and remove the focus screen.
3. Place the viewnder mask in the bracket that holds the focusing screen.
4. Re-mount the viewnder focus screen.
5. Slide the waist-level nder back into place.
N.B. Please check the relevant Hasselblad camera manual instructions before
removing the focus screen.