126
15.5 Hasselblad 553 ELX
When using the IQ back on some Hasselblad motorized bodies (i.e. Hasselblad
ELX or Hasselblad ELM series), a motor cable is supplied to enable users to
re the camera shutter from a computer using the Capture One Pro Capture
button. (See circled button left).
Cable Connections
The cable is connected between the multi-connector on the IQ back and the
DIN connector on the Hasselblad. Ensure that A or AS mode are not used.
WARNING! Please note that the Phase One IQ back should not be mounted
while the camera is set to mirror up (S or RS modes). Make sure that the lens
is not jammed or locked open on the “B” setting when connecting the ash
sync cable to the Phase One IQ back.
Shutter Latency Setting
Set the latency setting to Normal on the IQ back while using a Hasselblad
553 ELX.