PHILIPS 4000 and 3000 04 OPERATING LOGIC
6/10
Notes: * Only with Pre-brewing
4.5. Coffee cycle
Switching on
Whenthemachineisswitchedon,thegearmotorrepositionsitselfasfollows:
- It acts on microswitch 1 (see following chapter).
- The gear motor changes its rotation direction and moves upwards again by approx. 1-2 mm.
-Theboilerbeginstoheatthewaterforapprox.45sec.,atfullpower,inordertoreachthe
optimal temperature. The temperature will then remain at a constant level.
Coffee cycle
1. The coffee grinder starts the grinding process (controlled by Time).
2. The gear motor (brewing unit) moves to the brewing position.
3. Preliminarydispensingphase(shortpumpactivity,shortpause).
4. Productdispensing(thepumpoperationperiodisdenedbytheamountofproductdis-
pensed).
5. The gear motor moves to its home position (the dregs are expelled automatically).
Main switch ON START STOP
Time
Coffee grinder
Heating
Pump
Brewing unit gear
motor
Status Heating Ready Coffee cycle
Time
(Dosage)
Pumpoperation(ow
meter pulses) in
accordance with the
amount of product
selected.
approx.
45 sec.
*
Single microswitch gear motor
Status
Microswitch
OFF
ON