ErgoLine D310/320
Customer Engineer Manual
Page 5-10
Programming
For full programming instructions, see the userguide.
It is also possible for the system engineer to protect the D320 against unauthorised
programming. This is done as described below:
Terminal (Un)locking of the D320
Terminal locking offers the possibility to block
programming of the EAZ only, or
programming of any parameters of the terminal by unauthorised users.
Locking of EAZ:
press PROGRAM key
press “159”
press PROGRAM key
press “1” to lock EAZ programming
press PROGRAM key.
It is now not possible to change the EAZ.
Unlocking of EAZ:
press PROGRAM key
press “159”
press PROGRAM key
press “0” to unlock EAZ programming
press PROGRAM key.
Locking of all programming
press PROGRAM key
press “159”
press PROGRAM key
press “9” to lock all programming
press PROGRAM key.
It is now not possible to change any setting of the terminal.
Unlocking of all programming:
disconnect terminal
press ‘4’ and ‘6’ key simultaneously while reconnecting the terminal.