PDP-507CMX
173
5678
56
7
8
C
D
F
A
B
E
Factory related command
Command Operation
Command Effectiveness Numeric Direct input
Remarks
Factory
Normal 
Operation
Validity Minimum Maximum
Operation mode selection
FAN Turning the factory mode OFF O - - - -
FAY Turning the factory mode ON - O - - -
FALS00 Turning the factory mode lock OFF O - - - -
FALS01 Turning the factory mode ON O - - - -
Power supply control of drive system
DRVS00 Turning the power of drive system OFF O O - - -
DRVS01 Turning the power of drive system ON O O - - -
Various adjustment of the main side
MAJS00
Starting the W/B and LPF auto adjustment of the MAIN Assy
O ----
MAJS01
Forcibly finishing the W/B and LPF auto adjustment of the MAIN Assy
O ----
ADC*** Adjusting the AD contrast O - O 000 255
MRG*** Adjusting the R GAIN of AD MAIN O - O 000 255
MRO*** Adjusting the R OFFSET of AD MAIN O - O 000 255
MGG*** Adjusting the G GAIN of AD MAIN O - O 000 255
MGO*** Adjusting the G OFFSET of AD MAIN O - O 000 255
MBG*** Adjusting the B GAIN of AD MAIN O - O 000 255
MBO*** Adjusting the B OFFSET of AD MAIN O - O 000 255
SRG*** Adjusting the R GAIN of AD SUB O - O 000 255
SRO*** Adjusting the R OFFSET of AD SUB O - O 000 255
SGG*** Adjusting the G GAIN of AD SUB O - O 000 255
SGO*** Adjusting the G OFFSET of AD SUB O - O 000 255
SBG*** Adjusting the B GAIN of AD SUB O - O 000 255
SBO*** Adjusting the B OFFSET of AD SUB O - O 000 255
Various control of the main side
FCNS00 Setting the fan roll control to stop O - - - -
FCNS01 Setting the fan roll control to maximum O - - - -
FCNS02 Setting the fan roll control to middle O - - - -
FCNS03 Setting the fan roll control to weak O - - - -
FCNS04 Setting the fan roll control to auto O - - - -
FCNS99 Setting the fan roll control to TEST O - - - -
FOF
Requesting the fan abnormality detection O
-
-
-
-
LEDS00 Turning off the all front indicators O - - - -
LEDS02 Setting the front indicators to normal operation O - - - -
LEDS10 Front indicators: ON (green) O - - - -
LEDS11 Front indicators: STANDBY (red) O - - - -
EDWS00 Prohibiting writing of EDID data O - - - -
EDWS01 Permitting writing of EDID data O - - - -
EPAS00 Prohibiting EEPROM access from the outside O - - - -
EPAS01 Permitting EEPROM access from the outside O - - - -
ACK→ S01 : Normal