EasyManua.ls Logo

Postek G2000e - Page 48

Postek G2000e
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
G2000e/G3000e/G6000e Users Manual Appendix A: Interface Specifications
43
Appendix
A: Interface Specifications
The RS232 connector on the printer is a DB9F:
Number
Description
Definition
1
/
/
2
Out
TX
3
In
RX
4
/
/
5
-
Ground
6
/
/
7
/
/
8
/
/
9
/
/
Baud rate: 9600, 19200, 38400, 57600 and 115200
Data format: 8 data bits, 1 start bit or 1 stop bit.
Flow control: None. If you are using software or drivers under the Windows environment, the flow
control must be set to “hardware.
Any communications port can transmit data from the host (RS232, Ethernet, or USB). Preliminary
communications settings are not required since the printer will automatically detect which port is
active.
Never send data from 2 ports at the same time. Data cannot be sent to more than one port
simultaneously or data corruption and print errors may occur.