EasyManua.ls Logo

PR 9116 - Page 45

PR 9116
79 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9116 - Product Version 9116-003 43
9116QF01
LERBAKKEN 10, 8410 ROENDE DENMARK
Revision date:
2012-06-08
Version Revision
V6 R0
Prepared by:
PB
Page:
4/4
Ui, Vmax 30 V
Ii, Imax 120 mA
Pi 900 mW
Ci 3 nF
Li 2 μH
Terminal 51-52
Module 9116B 1/2
Uo, Voc 16.6 V
IIC or A,B
0.4 μF 100 mH 25mH/
Io, Isc 0.2 mA
IIB or C,E,F
2.3 μF 100 mH 100mH/
Po 0.8 mW
IIA or D,G
9.5 μF 100 mH 200mH/
Lo Lo/Ro
Module 9116B 1/2
Terminals 51-52
Group Co
+
-
54
53
52
51
44
43
42
41
9116
34
33
32
31
14
13
12
11
Power Rail
4501
54
53
52
51
44
43
42
41
9116
34
33
32
31
14
13
12
11
Power Rail
4501
(terminal 11,12,13,14)
(terminal 31,32,33,34)
(terminal 91,92,93,94,95)
U
m:
253 V max. 400 Hz
Hazardous Classified Location
Class I/II/III, Division 1, Group A,B,C,D,E,F,G
or Class I, Zone 0/1 Group IIC, [AEx ia] IIC
or Class I, Zone 0/1 Group IIC, [Ex ia] IIC
Unclassified Location or
Hazardous Classified Location
Class I, Division 2 Group A,B,C,D T4
or Class I, Zone 2, Group IIC T4
0/4-20 mA
Current Source
-20 ºC Ta +60ºC
Status relay, terminal (33,34)
Unclassified location installation:
Voltage max: 125 VAC / 110 VDC
Power max: 62.5 VA / 32 W
Current max: 0.5 A AC / 0.3 ADC
Zone 2 installation:
Voltage max: 32 VAC/ 32 VDC
Power max: 16 VA / 32 W
Current max: 0.5 A AC / 1 A DC
Relay output, terminal (13,14)
Unclassified location installation:
Voltage max: 250 VAC / 30 VDC
Power max: 500 VA / 60 W
Current max: 2 A AC / 2 ADC
Zone 2 installation
Voltage max: 32 VAC / 30 VDC
Power max: 64 VA / 60 W
Current max: 2 A AC / 2 ADC

Table of Contents

Related product manuals