13
Step 4: Cleaning Catalyst
WARNING: The Catalytic Converter must remain inside the oven
during operation. Only clean when the unit is not in use.
Remove the oven rack and bottom jetplate. (Refer to step 1 & 2 for
instructions on how to remove the rack and jetplate).
Lift the catalytic converter up out of the holding bracket.
Clean the catalytic converter using the approved cleaning materials
and allow to dry prior to reinstalling back in unit.
The catalyst does not have to be cleaned daily if it is not contaminated
with food particles but must be cleaned quarterly. Please refer to
quarterly cleaning for further instructions.
Step 5: Cleaning Air Filter
WARNING: Filter must be installed during oven use. Only remove
to clean when oven is not in use.
The air filter is located under the removable front panel under the
door.
Locate the tab on the filter and pull towards the front of the unit.
Rinse the filter in hot water to remove any buildup and allow the filter
to dry prior to reinstalling.
Step 6: Removing Food Particles from Cavity
If food particles remain on the bottom of the cavity, the IR element
can be lifted for better access.
The best way to remove food particles is with a damp cloth but a food
vacuum can also be used.
WARNING: Do not attempt to spray the IR element directly. If any
particles are stuck to the element. Allow the element to cool down
completely and wipe off with dry cloth.
Step 4
Step 6
Step 5