59
Door Switch Adjustments
LED lights are used on the control board to indicate the position of the contacts of the three door
switches. When the LED is illuminated, the switch position is opened and vice versa. The control board
identifies the LED’s as SW1 (Primary) and SW2 (Secondary).
The LED’s will illuminate when the over power is connected, (and the door is opened). The oven does
not need to be in the “ON” position to test the switch positions. Care should be taken when servicing
the oven with the power connected. Observe the LED’s from a safe distance.